You are not allowed to view this content.
Custom Content

  • Certificate Number 8198
  • Date 09/24/2025
  • Client ID 1450
  • Client Kinder Morgan
  • Primary Address 4301 Iverson Blvd Suite B
    Trinity, Alabama 35673
    Map It
  • Billing Address 4301 Iverson Blvd Suite B
    Trinity, Alabama
    Map It
  • Contact Name Chris Prince
  • Contact Phone 256-274-3810
  • Contact Email chris_prince@kindermorgan.com
  • Purpose of Inspection Annual
  • Certificate issued under CMS
  • Applicable Standard B30.25
  • If CMS Certificate
    • General Industry
  • Date of last Annual 09/24/2025
  • Certificate Type
    • Annual
  • Owner's Identification of Unit 55976
  • Description
    • Other
  • If Other Material Handler
  • Location Description
    • Remains at worksite
  • Unit Location Description Trinity, AL
  • Manufacturer Liebherr
  • Model Number LH 110-M
  • Serial Number WLHZ1227CZK155976
  • Service at Time of Survey
    • Magnet
  • Boom Length 72
  • Boom Type Boxed Hinged
  • Boom Type Boxed Hinged
  • Minimum Radius 15
  • Maximum Proof Load N/A
  • Maximum Rated Load 68340
  • Intermediate Radius 35
  • Intermediate Proof Load N/A
  • Intermediate Rated Load 34200
  • Maximum Radius 70
  • Minimum Proof Load N/A
  • Minimum Rated Load 15825
  • Means of Application N/A
  • Basis for load ratings Manufacturer's Load Rating Chart
  • Remarks, Limitations None noted
  • Load Indicating or Limiting Device Not Fitted
  • Device Accuracy N/A
  • Inspector Name Kevin Fowler